LIU Xian-yong, HUANG Feng-lei, WANG Xia, ZHOU Fang-jie. Optimum Optical Length of the Gas Cell Used for Monitoring Gas-In-Oil with FTIR[J]. JOURNAL OF BEIJING INSTITUTE OF TECHNOLOGY, 2003, 12(1): 59-63.
Citation: LIU Xian-yong, HUANG Feng-lei, WANG Xia, ZHOU Fang-jie. Optimum Optical Length of the Gas Cell Used for Monitoring Gas-In-Oil with FTIR[J].JOURNAL OF BEIJING INSTITUTE OF TECHNOLOGY, 2003, 12(1): 59-63.

Optimum Optical Length of the Gas Cell Used for Monitoring Gas-In-Oil with FTIR

  • Received Date:2002-05-21
  • Dedicated experiments are designed to collect the infrared spectra of dissolved gas-in-oil of power transformers. Spectra of diagnostic gases are collected by 3 different laboratorial FTIR spectrometers using 3 different gas cells with various sets of equipment parameters. A formula is deduced to calculate the shortest optical length to detect a specific concentration according to measurements on gases with known concentrations near to the minimum detection limit. Collected spectra and calculated results suggested that the optimum optical length of the gas cell should be 150 mm to realize on-line monitoring of diagnostic gases within the required concentration range. At the end, an economic novel design of the gas cell is proposed based on the optimum length.
  • loading
  • [1]
    Wang Zhenyuan.A rtificial intelligence applications in thediagnosis of pow er tr ansformer incipient faults[D].Blacksburg,V irginia:V irg inia Polytechnic Institute andState University,2000.6-16.
    [2]
    Y ang Li,Shang Y ong,Yan Zhang.T rend of conditionbased monitoring of pow er transformer abr oad[J].H ighVoltage Eng ineering,1999,25(3):37-39.(in Chinese)
    [3]
    Jia Ruijun.Review about gas disso lved in tr ansformer oilon line detection[J].Pow er System T echnolo gy,1998,22(5):49-55.(in Chinese)
    [4]
    Zhang G uanjun,Q ian Zheng,Yan Zhang.Applicationand dev elopment of DGA techno logy for insulation faultdiagnosis of pow er transformers[J].T r ansformer,1999,36(1):30-34.(in Chinese)
    [5]
    Y ang Q iping,Xue W ude,L an Zhida.Application of g assensor in transformer on line monitoring[J].T ransformer,2001,38(2):36-38.(in Chinese)
    [6]
    Wu Hao yang,Chang Bingguo,Zhu Changchun,et al.G as sensor ar ray system for analyzing fault in transformer[J].J of X?ian Jiaotong U niversity,2000,34(4):23-25.(in Chinese)
    [7]
    Sparling B.M anaging the life of transformers[Z].RCMfor Substation,T ransmission and Distribution Conference,[s.l.],1999.17-19.
    [8]
    Wang Hui,Zhao Xiuge,Xiao W ende,et al.Q uant itat iveanalysis of multi component w ith F T IR and its application[J].Journal of East China U niversity of Science andT echnolog y,2001,27(1):1-5.(in Chinese)
  • 加载中

Catalog

    通讯作者:陈斌, bchen63@163.com
    • 1.

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (88) PDF downloads(2) Cited by()
    Proportional views
    Related

    /

      Return
      Return
        Baidu
        map